Sale!

Best Price Victron LYN034170310 Lynx Smart BMS 1000 NG M10

Original price was: $1,071.00.Current price is: $428.40.

SKU: SK0018115-US20260519-084255 Category:

Description

Victron LYN034170310 Lynx Smart BMS 1000 NG M10

Victron LYN034170310 Lynx Smart BMS 1000 NG M10. The Lynx Smart BMS NG is a dedicated Battery Management System (BMS) designed specifically for the Victron Lithium NG batteries. These batteries utilize Lithium Iron Phosphate (LiFePO4) technology and are available in 12.8 V, 25.6 V, and 51.2 V variants with various capacities. They can be configured in series, parallel, and series/parallel arrangements, allowing for the creation of battery banks with system voltages of 12V, 24V, 36V or 48V.

The maximum number of batteries in a single system is 50, enabling a maximum energy storage of 192kWh in a 12V system and up to 384kWh in a 24V and 48V system. For comprehensive details about these batteries, visit the Victron Lithium NG battery product page. Out of the various BMSes available for the Lithium NG batteries, the Lynx Smart BMS NG is the most feature-rich and complete option and integrates seamlessly with other M10 products in the Lynx Distributor system. It is the 1000 A (M10) version.

Built-in 1000 A Contactor Lynx Smart BMS NG 1000A Available in 1000 A (M10) version. Acts as a secondary safety system to protect the battery in case primary controls (ATC, ATD, and/or DVCC) fail. Suitable as a remote controllable main system switch

Specifications
Battery Voltage Range: 9 – 60 VDC
Maximum Input Voltage: 75 VDC
Supported System Voltages: 12, 24, or 48 V
Reverse Polarity Protection: No
Main Safety Contactor Continuous Current Rating: 1000 A continuous
Main Safety Contactor Peak Current Rating: 1200 A for 5 minutes
Power Consumption OFF Mode: 0.3 mA for all system voltages
Power Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V)
Power Consumption in ON Mode: Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays
Minimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems
AUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuse
Allow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by resettable fuse
Allow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by resettable fuse
Alarm Relay (SPDT) Maximum Current Rating: 2 A at 60 VDC

Connections
Busbar: M10 (Torque: 33 Nm) – can be combined with all M10 Lynx products
VE.Can: RJ45
I/O: Removable multi-connector with screw terminals
Battery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 50 batteries can be connected in one system
Lynx Distributor Fuse Monitoring (up to 4 modules): RJ10 (cable ships with each Lynx Distributor)

Call 575-539-2111 With Questions